Model Series |
: |
RLUA(Sizes: 15 to 500 mm) |
Measuring Principle |
: |
Transit Time analysis |
Measurement |
: |
On-line, Continuous, Bi-directional |
Accuracy |
: |
(+/ - ) 1% to 1.5% of span ( Calibrated as ISO 4064 ) |
Repeatability |
: |
Better than 0.2 % of span |
|
|
Applications |
: |
Clear Fluids ,like potable water,pure water , etc .Not recommended for dirty water |
Power Supply |
: |
3.6 V Li Battery powered ( applications where AC/DC power not available )
Battery life ( one data per day ) 5 to 7 years or more (depending on usage & environment
|
Certification |
: |
: ISO 4064 ( as per MID/EEC ) |
Corrosion Resistance |
: |
Good due to Bronze material |
|
|